EXIN CDCS QUESTIONS - GET VERIFIED CDCS DUMPS (2025)

EXIN CDCS Questions - Get Verified CDCS Dumps (2025)

EXIN CDCS Questions - Get Verified CDCS Dumps (2025)

Blog Article

Tags: Training CDCS Material, Reliable CDCS Exam Testking, Latest CDCS Version, Real CDCS Torrent, CDCS Cert Exam

Whereas the EXIN EPI Certified Data Centre Specialist (CDCS) PDF dumps file offered by the GuideTorrent is simply a collection of real EXIN EPI Certified Data Centre Specialist (CDCS) exam questions that prepare you quickly for the final CDCS certification exam. Choose the right GuideTorrent CDCS Exam Questions formats and start this journey as soon as possible and become a certified EXIN CDCS exam expert. Best of luck in exams and career!!

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 2
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.
Topic 3
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.

>> Training CDCS Material <<

Pass Guaranteed 2025 EXIN Professional CDCS: Training EXIN EPI Certified Data Centre Specialist Material

Full refund is available if you fail to pass the exam in your first attempt after buying CDCS exam bootcamp from us, and we will refund your money, In addition, CDCS exam dumps contain both questions and answers, and it’s convenient for you to check the answers after practicing. CDCS exam botcamp cover most of the knowledge points of the exam, and you can master the major knowledge points as well as improve your professional ability in the process of training. We have online and offline chat service for CDCS Exam Dumps, and if you have any questions, you can consult us.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q52-Q57):

NEW QUESTION # 52
What is a significant difference between a halocarbon gas-based fire suppression system and an inert gas-based fire suppression system?

  • A. Inert gas has smaller-sized gas containers than halocarbon gas.
  • B. Halocarbon gas works on the basis of oxygen reduction and inert gas works on the basis of heat removal.
  • C. Halocarbon gas works on the basis of heat removal and inert gas works on the basis of oxygen reduction.
  • D. Inert gas harms the environment and halocarbon gas does not.

Answer: C

Explanation:
A halocarbon gas-based fire suppression system primarily extinguishes fires through heat absorption. In contrast, an inert gas-based system works by reducing oxygen levels to a point where combustion cannot be sustained. Halocarbon agents, like FM-200, absorb heat from the fire, cooling it down, whereas inert gases, like nitrogen or argon, lower oxygen concentration.
Detailed Explanation:
Halocarbons are effective in quickly cooling flames and are suitable for electronic environments due to their fast action. Inert gases displace oxygen to suppress fires, making them ideal in occupied spaces where human safety can be managed during a fire event due to slower discharge times.
EPI Data Center Specialist References:
EPI training distinguishes between these suppression mechanisms, noting the importance of selecting the correct system based on specific needs like quick response versus oxygen displacement for environments with sensitive equipment.


NEW QUESTION # 53
A computer room with a raised floor has been designed with racks in a hot/cold aisle setup.
What should you recommend for the placement of down-flow air conditioners?

  • A. Air conditioner placement has no influence on cooling effectiveness and efficiency. Hence, they can be placed at any convenient location.
  • B. Air conditioners perpendicular to (at the end of the row of) the Hot-Aisle
  • C. Air conditioners should always be placed at both sides of each row of racks
  • D. Air conditioners perpendicular to (at the end of the row of) the Cold-Aisle

Answer: D

Explanation:
In a hot/cold aisle configuration, placing down-flow air conditioners perpendicular to the cold aisle ensures that cool air is directed efficiently into the cold aisles where server intakes are located. This layout allows for optimal cooling performance by aligning the airflow directly with the equipment intakes, minimizing hot spots and enhancing cooling efficiency.
Detailed Explanation:
With a raised floor design, cold air from the air conditioners is supplied into the cold aisle, where server intakes are located. Positioning the air conditioning units perpendicular to the cold aisles ensures that cool air is delivered directly into these aisles, preventing air mixing and optimizing cooling. This setup takes full advantage of the airflow management strategy inherent to the hot/cold aisle configuration.
EPI Data Center Specialist References:
EPI guidelines on cooling emphasize that down-flow air conditioners should be positioned to maximize the effectiveness of cold aisle delivery, which improves cooling efficiency and helps maintain consistent temperatures across server racks.


NEW QUESTION # 54
What should you consider when using raised floor tiles with air deflectors or louvers?

  • A. Tiles with air deflectors or louvers do not allow for a flexible cooling solution.
  • B. Tiles with air deflectors or louvers can be very heavy.
  • C. Tiles with air deflectors or louvers can only be used to cool storage equipment.
  • D. Tiles with air deflectors or louvers will reduce the cooling capacity of the tile.

Answer: B

Explanation:
Raised floor tiles with air deflectors or louvers are typically heavier than standard tiles due to the additional materials and mechanisms used to direct airflow. The added weight can pose challenges for installation and adjustment, and consideration must be given to the floor's load capacity and ease of maintenance.
Detailed Explanation:
Tiles with deflectors or louvers help direct airflow, enhancing cooling efficiency by focusing cool air where needed. However, these tiles are often heavier, which can affect handling and require reinforced raised floor systems. It's essential to factor in the weight for any floor tile replacements or installations to ensure they are compatible with the raised floor's structural capacity.
EPI Data Center Specialist References:
EPI data center design training mentions the potential impact of heavy tiles on floor handling and load capacity. Data center operators need to plan for safe handling and load-bearing capacity when using such specialized tiles.


NEW QUESTION # 55
A data center requires an audit to find out whether it conforms with ANSI/TIA-942 Rated-3 (concurrently maintainable).
Will the network architecture be part of this audit?

  • A. Yes, amongst other aspects, the network architecture should be Rated-3 compliant with the requirements of ANSI/TIA-942.
  • B. No, only the type of cabling used will be audited.
  • C. Yes, but only if the network administration does not comply with ANSI/TIA-606.
  • D. No, as concurrently maintainable only applies to electrical and mechanical (power and cooling).

Answer: A

Explanation:
For a Rated-3 data center, network architecture is indeed a key component of the audit under ANSI/TIA-942. This rating requires concurrent maintainability across all systems, including telecommunications infrastructure. The network architecture must therefore meet specific redundancy and reliability standards to ensure uninterrupted operations during maintenance or failure of any single component.
Detailed Explanation:
Rated-3 requirements extend beyond electrical and mechanical systems to include network architecture. This ensures that telecommunications systems are also designed for concurrent maintainability, thus contributing to overall uptime and resilience.
EPI Data Center Specialist References:
EPI endorses comprehensive assessments for Rated-3 facilities, emphasizing that network systems must meet standards for redundancy and concurrent maintainability, which align with ANSI/TIA-942's holistic approach to data center reliability.


NEW QUESTION # 56
What precaution shall be taken for cabling leading into an equipment rack when a data center is in a seismic-prone area?

  • A. Cables should be loosely organized to allow for movement and be latched at the connectors.
  • B. Cables shall be tightly organized to the rack and trays to avoid movement.
  • C. Cables should be replaced by busbar trunking.
  • D. Cables can be organized in any way as it is not important.

Answer: B

Explanation:
In seismic-prone areas, cables should be tightly secured to racks and cable trays to minimize movement during seismic activity. Properly securing the cables prevents them from being damaged due to excessive motion, which could lead to outages or damage to connected equipment.
Detailed Explanation:
Loose cables can be vulnerable to shaking or sudden jolts during an earthquake, increasing the risk of disconnection or damage. By tightly organizing and securing cables, you ensure they remain in place, even during significant movement, thereby maintaining connection integrity and reducing the risk of physical damage.
EPI Data Center Specialist References:
EPI training includes considerations for data centers in seismic zones, advising that cables be firmly anchored to support structures to reduce movement and mitigate potential damage during seismic events.


NEW QUESTION # 57
......

Our CDCS certification material is closely linked with the test and the popular trend among the industries and provides all the information about the CDCS test. The answers and questions seize the vital points and are verified by the industry experts. Diversified functions can help you get an all-around preparation for the test. Our online customer service replies the clients' questions about our CDCS Certification material at any time. So our CDCS learning file can be called perfect in all aspects.

Reliable CDCS Exam Testking: https://www.guidetorrent.com/CDCS-pdf-free-download.html

Report this page